Climate Zone 3A: Warm - Humid

Mixed climate with warm, humid summers and cool winters. Balanced heating and cooling needs.

Load Characteristic
Balanced Loads
Moisture Regime
Humid
States Covered
9 States

ASHRAE Design Temperatures

Official design temperatures for Climate Zone 3A per ASHRAE Fundamentals 2021. These values are critical for accurate Manual J load calculations.

Winter Design Temp
22°F

99% design temperature for heating load calculations (coldest expected temperature)

Summer Design Temp
94°F

1% design temperature for cooling load calculations (hottest expected temperature)

Wet Bulb Temp
75°F

Summer wet-bulb for latent cooling load and dehumidification calculations

2021 IECC Insulation Requirements

Minimum insulation and window specifications for Climate Zone 3A per the International Energy Conservation Code (IECC) 2021.

Wall Insulation
R-20

Minimum wall R-value (continuous insulation or cavity + continuous)

Roof/Ceiling Insulation
R-30

Minimum attic/ceiling R-value for energy compliance

Floor Insulation
R-19

Minimum floor R-value (over unconditioned space)

Window U-Factor
0.32

Maximum window U-factor (lower is better insulation)

Window SHGC
0.25

Maximum Solar Heat Gain Coefficient

Air Infiltration
0.15

Typical ACH (air changes per hour) for load calculations

Moisture Regime: Humid

High humidity climate requiring significant moisture control

Key Considerations for Humid Climates:

  • High dehumidification loads
  • Mold/mildew prevention critical
  • Proper vapor barriers essential

Recommended HVAC Equipment

Typical equipment specifications for Climate Zone 3A installations.

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

States in Climate Zone 3A

Climate Zone 3A covers 9 states across the United States. Click a state to see city-specific climate data and Manual J load calculations.

Frequently Asked Questions About Climate Zone 3A

Q1What states are in Climate Zone 3A?

Climate Zone 3A includes parts of Alabama, Arkansas, Georgia, Mississippi, North Carolina, Oklahoma, South Carolina, Tennessee, and Texas. This zone represents a balanced climate with humid moisture conditions.

Q2What are the design temperatures for Zone 3A?

The official ASHRAE design temperatures for Climate Zone 3A are:

  • Winter 99% Design Temp: 22°F
  • Summer 1% Design Temp: 94°F
  • Summer Wet Bulb: 75°F

Q3What equipment works best in Climate Zone 3A?

For Climate Zone 3A (Warm - Humid), recommended HVAC equipment includes:

Heating Systems:
  • Gas furnace
  • Heat pump

Typical AFUE: 90-95%

Cooling Systems:
  • AC (14-16 SEER)
  • Heat pump

Typical SEER: 14-16 SEER

Q4What R-value insulation is required in Zone 3A?

IECC 2021 requires the following minimum R-values for Climate Zone 3A:

Walls
R-20
Roof
R-30
Floor
R-19
Window U
0.32

Q5Is Zone 3A heating-dominated or cooling-dominated?

Climate Zone 3A is a balanced climate. This means heating and cooling loads are relatively balanced, requiring careful sizing of both heating and cooling equipment.

Q6What is the moisture regime for Zone 3A?

Zone 3A has a humid moisture regime. This means high humidity levels, significant dehumidification requirements in summer, and careful attention to latent cooling loads in Manual J calculations.

Get Accurate Load Calculations for Zone 3A

Our AI-powered Manual J calculator uses official Zone 3A design temperatures and IECC requirements for pinpoint accuracy. First report is FREE.

Upload Blueprint → Get Free Manual J