What Climate Zone is Webster County, LA?

Webster County is in IECC Climate Zone 3A (Warm - Humid). Get accurate Manual J load calculations with official ASHRAE design temperatures for Webster County.

IECC Climate Zone
3A
Winter 99% Design
25°F
Summer 1% Design
98°F
ZIP Codes
11
Cities
1

Webster County, Louisiana is classified under IECC Climate Zone 3A (Warm - Humid), a mixed-climate region with humid moisture conditions. With 11 ZIP codes and 1 communities, every HVAC installation in Webster County must use the ASHRAE design temperatures of 25°F (99% winter heating) and 98°F (1% summer cooling) for accurate Manual J load calculations.

With balanced heating and cooling loads, Webster County homes require well-rounded insulation — R-20 walls, R-30 ceilings, R-19 floors — and windows with both U-factor 0.32 and SHGC 0.25 to handle both winter lows and summer highs.

Webster County Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance for Climate Zone 3A in Webster County, LA.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Webster County HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3A requires precise load calculations. Upload your Webster County blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Webster County's exact design temperatures (25°F winter / 98°F summer).

Claim Free Report
No credit card required

Verify Your Webster County ZIP Code

Enter your ZIP code to confirm it's in Webster County and get climate zone details.

Webster County covers 11 ZIP codes including: 71018, 71021, 71023, 71024, 71039, 71055, 71058, 71071 and 3 more

Webster County Design Temperatures

Official ASHRAE design temperatures for Webster County, LA, used for accurate Manual J load calculations.

Winter 99% Design Temp
25°F
Heating load calculation baseline
Summer 1% Design Temp
98°F
Cooling load calculation baseline
Summer Wet Bulb
75°F
Latent load (humidity) calculation

IECC Zone 3A Insulation Requirements

Minimum insulation and window requirements for Webster County per IECC 2021 energy code.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Climate Zone 3A: Warm - Humid - Mixed climate with warm, humid summers and cool winters. Balanced heating and cooling needs.

Cities in Webster County, LA

1 cities and communities in Webster County share Climate Zone 3A requirements.

Recommended HVAC Equipment for Webster County

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Nearby Counties in Louisiana

Compare climate zones with other counties in Louisiana. Different zones require different HVAC equipment sizing.

Get Free Manual J Calculations for Webster County

Upload your Webster County blueprint and get a professional Manual J load calculation using official Zone 3A design temperatures. First report is FREE.

Webster County design temps
Zone 3A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Louisiana contractors who trust AutoHVAC