Climate ZonesLouisianaAscension County

What Climate Zone is Ascension County, LA?

Ascension County is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official ASHRAE design temperatures for Ascension County.

IECC Climate Zone
2A
Winter 99% Design
30°F
Summer 1% Design
97°F
ZIP Codes
11
Cities
1

Ascension County, Louisiana is classified under IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. With 11 ZIP codes and 1 communities, every HVAC installation in Ascension County must use the ASHRAE design temperatures of 30°F (99% winter heating) and 97°F (1% summer cooling) for accurate Manual J load calculations.

As a cooling-dominated zone, controlling solar heat gain is essential in Ascension County. Windows must have an SHGC of 0.25 or lower, along with R-13 wall and R-30 ceiling insulation. Proper sizing prevents oversized AC systems that short-cycle and waste energy.

Ascension County Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance for Climate Zone 2A in Ascension County, LA.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Ascension County HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your Ascension County blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Ascension County's exact design temperatures (30°F winter / 97°F summer).

Claim Free Report
No credit card required

Verify Your Ascension County ZIP Code

Enter your ZIP code to confirm it's in Ascension County and get climate zone details.

Ascension County covers 11 ZIP codes including: 70346, 70707, 70718, 70725, 70728, 70734, 70737, 70738 and 3 more

Ascension County Design Temperatures

Official ASHRAE design temperatures for Ascension County, LA, used for accurate Manual J load calculations.

Winter 99% Design Temp
30°F
Heating load calculation baseline
Summer 1% Design Temp
97°F
Cooling load calculation baseline
Summer Wet Bulb
77°F
Latent load (humidity) calculation

IECC Zone 2A Insulation Requirements

Minimum insulation and window requirements for Ascension County per IECC 2021 energy code.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Climate Zone 2A: Hot - Humid - Cooling-dominated with hot, humid summers and mild winters. Significant cooling loads with moderate heating needs.

Cities in Ascension County, LA

1 cities and communities in Ascension County share Climate Zone 2A requirements.

Recommended HVAC Equipment for Ascension County

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Nearby Counties in Louisiana

Compare climate zones with other counties in Louisiana. Different zones require different HVAC equipment sizing.

Get Free Manual J Calculations for Ascension County

Upload your Ascension County blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

Ascension County design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Louisiana contractors who trust AutoHVAC