Climate ZonesLouisianaAssumption County

What Climate Zone is Assumption County, LA?

Assumption County is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official ASHRAE design temperatures for Assumption County.

IECC Climate Zone
2A
Winter 99% Design
35°F
Summer 1% Design
93°F
ZIP Codes
6
Cities
1

Assumption County, Louisiana is classified under IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. With 6 ZIP codes and 1 communities, every HVAC installation in Assumption County must use the ASHRAE design temperatures of 35°F (99% winter heating) and 93°F (1% summer cooling) for accurate Manual J load calculations.

As a cooling-dominated zone, controlling solar heat gain is essential in Assumption County. Windows must have an SHGC of 0.25 or lower, along with R-13 wall and R-30 ceiling insulation. Proper sizing prevents oversized AC systems that short-cycle and waste energy.

Assumption County Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance for Climate Zone 2A in Assumption County, LA.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Assumption County HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your Assumption County blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Assumption County's exact design temperatures (35°F winter / 93°F summer).

Claim Free Report
No credit card required

Verify Your Assumption County ZIP Code

Enter your ZIP code to confirm it's in Assumption County and get climate zone details.

Assumption County covers 6 ZIP codes including: 70339, 70341, 70372, 70390, 70391, 70393

Assumption County Design Temperatures

Official ASHRAE design temperatures for Assumption County, LA, used for accurate Manual J load calculations.

Winter 99% Design Temp
35°F
Heating load calculation baseline
Summer 1% Design Temp
93°F
Cooling load calculation baseline
Summer Wet Bulb
77°F
Latent load (humidity) calculation

IECC Zone 2A Insulation Requirements

Minimum insulation and window requirements for Assumption County per IECC 2021 energy code.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Climate Zone 2A: Hot - Humid - Cooling-dominated with hot, humid summers and mild winters. Significant cooling loads with moderate heating needs.

Cities in Assumption County, LA

1 cities and communities in Assumption County share Climate Zone 2A requirements.

Recommended HVAC Equipment for Assumption County

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Nearby Counties in Louisiana

Compare climate zones with other counties in Louisiana. Different zones require different HVAC equipment sizing.

Get Free Manual J Calculations for Assumption County

Upload your Assumption County blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

Assumption County design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Louisiana contractors who trust AutoHVAC