Acadia County is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official ASHRAE design temperatures for Acadia County.

IECC Climate Zone
2A
Winter 99% Design
32°F
Summer 1% Design
94°F
ZIP Codes
11
Cities
1

Acadia County, Louisiana is classified under IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. With 11 ZIP codes and 1 communities, every HVAC installation in Acadia County must use the ASHRAE design temperatures of 32°F (99% winter heating) and 94°F (1% summer cooling) for accurate Manual J load calculations.

As a cooling-dominated zone, controlling solar heat gain is essential in Acadia County. Windows must have an SHGC of 0.25 or lower, along with R-13 wall and R-30 ceiling insulation. Proper sizing prevents oversized AC systems that short-cycle and waste energy.

Acadia County Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance for Climate Zone 2A in Acadia County, LA.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Acadia County HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your Acadia County blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Acadia County's exact design temperatures (32°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your Acadia County ZIP Code

Enter your ZIP code to confirm it's in Acadia County and get climate zone details.

Acadia County covers 11 ZIP codes including: 70516, 70525, 70526, 70527, 70531, 70534, 70537, 70543 and 3 more

Acadia County Design Temperatures

Official ASHRAE design temperatures for Acadia County, LA, used for accurate Manual J load calculations.

Winter 99% Design Temp
32°F
Heating load calculation baseline
Summer 1% Design Temp
94°F
Cooling load calculation baseline
Summer Wet Bulb
77°F
Latent load (humidity) calculation

IECC Zone 2A Insulation Requirements

Minimum insulation and window requirements for Acadia County per IECC 2021 energy code.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Climate Zone 2A: Hot - Humid - Cooling-dominated with hot, humid summers and mild winters. Significant cooling loads with moderate heating needs.

Cities in Acadia County, LA

1 cities and communities in Acadia County share Climate Zone 2A requirements.

Recommended HVAC Equipment for Acadia County

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Nearby Counties in Louisiana

Compare climate zones with other counties in Louisiana. Different zones require different HVAC equipment sizing.

Get Free Manual J Calculations for Acadia County

Upload your Acadia County blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

Acadia County design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Louisiana contractors who trust AutoHVAC