Climate ZonesLouisianaSt. Martin County

What Climate Zone is St. Martin County, LA?

St. Martin County is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official ASHRAE design temperatures for St. Martin County.

IECC Climate Zone
2A
Winter 99% Design
31°F
Summer 1% Design
94°F
ZIP Codes
4
Cities
1

St. Martin County, Louisiana is classified under IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. With 4 ZIP codes and 1 communities, every HVAC installation in St. Martin County must use the ASHRAE design temperatures of 31°F (99% winter heating) and 94°F (1% summer cooling) for accurate Manual J load calculations.

As a cooling-dominated zone, controlling solar heat gain is essential in St. Martin County. Windows must have an SHGC of 0.25 or lower, along with R-13 wall and R-30 ceiling insulation. Proper sizing prevents oversized AC systems that short-cycle and waste energy.

St. Martin County Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance for Climate Zone 2A in St. Martin County, LA.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

St. Martin County HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your St. Martin County blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with St. Martin County's exact design temperatures (31°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your St. Martin County ZIP Code

Enter your ZIP code to confirm it's in St. Martin County and get climate zone details.

St. Martin County covers 4 ZIP codes including: 70517, 70519, 70521, 70582

St. Martin County Design Temperatures

Official ASHRAE design temperatures for St. Martin County, LA, used for accurate Manual J load calculations.

Winter 99% Design Temp
31°F
Heating load calculation baseline
Summer 1% Design Temp
94°F
Cooling load calculation baseline
Summer Wet Bulb
77°F
Latent load (humidity) calculation

IECC Zone 2A Insulation Requirements

Minimum insulation and window requirements for St. Martin County per IECC 2021 energy code.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Climate Zone 2A: Hot - Humid - Cooling-dominated with hot, humid summers and mild winters. Significant cooling loads with moderate heating needs.

Cities in St. Martin County, LA

1 cities and communities in St. Martin County share Climate Zone 2A requirements.

Recommended HVAC Equipment for St. Martin County

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Nearby Counties in Louisiana

Compare climate zones with other counties in Louisiana. Different zones require different HVAC equipment sizing.

Get Free Manual J Calculations for St. Martin County

Upload your St. Martin County blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

St. Martin County design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Louisiana contractors who trust AutoHVAC