What Climate Zone is St. Martin, Louisiana?

St. Martin is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official design temperatures for St. Martin.

Climate Zone
2A
Winter Design
32°F
Summer Design
95°F
ZIP Codes
4

St. Martin, Louisiana falls within IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. HVAC contractors working in St. Martin must use the official ASHRAE design temperatures of 32°F (99% winter) and 95°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2A is cooling-dominated, solar heat gain control is critical. St. Martin homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

St. Martin Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2A in St. Martin, Louisiana.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

St. Martin HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your St. Martin blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with St. Martin's exact design temperatures (32°F winter / 95°F summer).

Claim Free Report
No credit card required

Verify Your St. Martin ZIP Code

Enter your ZIP code to confirm it's in St. Martin and get climate zone details.

St. Martin covers 4 ZIP codes: 70517, 70519, 70521, 70582

St. Martin Design Temperatures

Official ASHRAE design temperatures for St. Martin, used for accurate Manual J load calculations.

Winter 99% Design Temp
32°F
Summer 1% Design Temp
95°F
Summer Wet Bulb
77°F

IECC Requirements for Zone 2A

Minimum insulation and window requirements for St. Martin per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2015 IECC

Recommended HVAC Equipment for St. Martin

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for St. Martin

Upload your St. Martin blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

St. Martin design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report