Climate ZonesLouisianaSt. Charles County

What Climate Zone is St. Charles County, LA?

St. Charles County is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official ASHRAE design temperatures for St. Charles County.

IECC Climate Zone
2A
Winter 99% Design
34°F
Summer 1% Design
93°F
ZIP Codes
10
Cities
1

St. Charles County, Louisiana is classified under IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. With 10 ZIP codes and 1 communities, every HVAC installation in St. Charles County must use the ASHRAE design temperatures of 34°F (99% winter heating) and 93°F (1% summer cooling) for accurate Manual J load calculations.

As a cooling-dominated zone, controlling solar heat gain is essential in St. Charles County. Windows must have an SHGC of 0.25 or lower, along with R-13 wall and R-30 ceiling insulation. Proper sizing prevents oversized AC systems that short-cycle and waste energy.

St. Charles County Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance for Climate Zone 2A in St. Charles County, LA.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

St. Charles County HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your St. Charles County blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with St. Charles County's exact design temperatures (34°F winter / 93°F summer).

Claim Free Report
No credit card required

Verify Your St. Charles County ZIP Code

Enter your ZIP code to confirm it's in St. Charles County and get climate zone details.

St. Charles County covers 10 ZIP codes including: 70030, 70031, 70039, 70047, 70057, 70070, 70078, 70079 and 2 more

St. Charles County Design Temperatures

Official ASHRAE design temperatures for St. Charles County, LA, used for accurate Manual J load calculations.

Winter 99% Design Temp
34°F
Heating load calculation baseline
Summer 1% Design Temp
93°F
Cooling load calculation baseline
Summer Wet Bulb
77°F
Latent load (humidity) calculation

IECC Zone 2A Insulation Requirements

Minimum insulation and window requirements for St. Charles County per IECC 2021 energy code.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Climate Zone 2A: Hot - Humid - Cooling-dominated with hot, humid summers and mild winters. Significant cooling loads with moderate heating needs.

Cities in St. Charles County, LA

1 cities and communities in St. Charles County share Climate Zone 2A requirements.

Recommended HVAC Equipment for St. Charles County

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Nearby Counties in Louisiana

Compare climate zones with other counties in Louisiana. Different zones require different HVAC equipment sizing.

Get Free Manual J Calculations for St. Charles County

Upload your St. Charles County blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

St. Charles County design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Louisiana contractors who trust AutoHVAC