What Climate Zone is Pierce, Wisconsin?

Pierce is in IECC Climate Zone 6A (Cold - Humid). Get accurate Manual J load calculations with official design temperatures for Pierce.

Climate Zone
6A
Winter Design
-9°F
Summer Design
89°F
ZIP Codes
11

Pierce, Wisconsin falls within IECC Climate Zone 6A (Cold - Humid), a heating-dominated region with humid moisture conditions. HVAC contractors working in Pierce must use the official ASHRAE design temperatures of -9°F (99% winter) and 89°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 6A is heating-dominated, insulation levels are critical. Pierce homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Pierce Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 6A in Pierce, Wisconsin.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Pierce HVAC Contractors: Get Your Free Manual J Report

Climate Zone 6A requires precise load calculations. Upload your Pierce blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Pierce's exact design temperatures (-9°F winter / 89°F summer).

Claim Free Report
No credit card required

Verify Your Pierce ZIP Code

Enter your ZIP code to confirm it's in Pierce and get climate zone details.

Pierce covers 11 ZIP codes: 54003, 54011, 54014, 54021, 54022, 54723, 54740, 54750, 54761, 54767 and 1 more

Pierce Design Temperatures

Official ASHRAE design temperatures for Pierce, used for accurate Manual J load calculations.

Winter 99% Design Temp
-9°F
Summer 1% Design Temp
89°F
Summer Wet Bulb
73°F

IECC Requirements for Zone 6A

Minimum insulation and window requirements for Pierce per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Pierce

Heating Systems

Gas furnace (96%+ AFUE)
Boiler
Cold climate heat pump
Typical AFUE
96-98%

Cooling Systems

AC (13-15 SEER)
Typical SEER
13-15 SEER

Get Free Manual J Calculations for Pierce

Upload your Pierce blueprint and get a professional Manual J load calculation using official Zone 6A design temperatures. First report is FREE.

Pierce design temps
Zone 6A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report