What Climate Zone is Langlade, Wisconsin?

Langlade is in IECC Climate Zone 7 (Very Cold). Get accurate Manual J load calculations with official design temperatures for Langlade.

Climate Zone
7
Winter Design
-18°F
Summer Design
87°F
ZIP Codes
10

Langlade, Wisconsin falls within IECC Climate Zone 7 (Very Cold), a heating-dominated region with moist moisture conditions. HVAC contractors working in Langlade must use the official ASHRAE design temperatures of -18°F (99% winter) and 87°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 7 is heating-dominated, insulation levels are critical. Langlade homes require a minimum of R-20 wall insulation, R-60 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Langlade Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 7 in Langlade, Wisconsin.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-60R-value
Wall InsulationR-20R-value
Floor InsulationR-38R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.45Coefficient
Air Infiltration0.15ACH50

Langlade HVAC Contractors: Get Your Free Manual J Report

Climate Zone 7 requires precise load calculations. Upload your Langlade blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Langlade's exact design temperatures (-18°F winter / 87°F summer).

Claim Free Report
No credit card required

Verify Your Langlade ZIP Code

Enter your ZIP code to confirm it's in Langlade and get climate zone details.

Langlade covers 10 ZIP codes: 54409, 54418, 54424, 54428, 54430, 54462, 54465, 54485, 54491, 54464

Langlade Design Temperatures

Official ASHRAE design temperatures for Langlade, used for accurate Manual J load calculations.

Winter 99% Design Temp
-18°F
Summer 1% Design Temp
87°F
Summer Wet Bulb
70°F

IECC Requirements for Zone 7

Minimum insulation and window requirements for Langlade per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-60
Floor Insulation:R-38
Window U-Factor:0.3
Window SHGC:0.45

Energy Code: 2021 IECC

Recommended HVAC Equipment for Langlade

Heating Systems

Gas furnace (97%+ AFUE)
Boiler
Cold climate heat pump with backup
Typical AFUE
97-98.5%

Cooling Systems

AC (minimal, 13 SEER)
Typical SEER
13 SEER

Get Free Manual J Calculations for Langlade

Upload your Langlade blueprint and get a professional Manual J load calculation using official Zone 7 design temperatures. First report is FREE.

Langlade design temps
Zone 7 compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Langlade contractors who trust AutoHVAC