Climate ZonesVirginiaPrince William

What Climate Zone is Prince William, Virginia?

Prince William is in IECC Climate Zone 4A (Mixed - Humid). Get accurate Manual J load calculations with official design temperatures for Prince William.

Climate Zone
4A
Winter Design
13°F
Summer Design
91°F
ZIP Codes
22

Prince William, Virginia falls within IECC Climate Zone 4A (Mixed - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Prince William must use the official ASHRAE design temperatures of 13°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4A experiences both significant heating and cooling loads. Prince William homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Prince William Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4A in Prince William, Virginia.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Prince William HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4A requires precise load calculations. Upload your Prince William blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Prince William's exact design temperatures (13°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Prince William ZIP Code

Enter your ZIP code to confirm it's in Prince William and get climate zone details.

Prince William covers 22 ZIP codes: 20109, 20111, 20112, 20136, 20143, 20155, 20169, 20181, 22026, 22125 and 12 more

Prince William Design Temperatures

Official ASHRAE design temperatures for Prince William, used for accurate Manual J load calculations.

Winter 99% Design Temp
13°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 4A

Minimum insulation and window requirements for Prince William per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Prince William

Heating Systems

Gas furnace (90%+ AFUE)
Heat pump
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Prince William

Upload your Prince William blueprint and get a professional Manual J load calculation using official Zone 4A design temperatures. First report is FREE.

Prince William design temps
Zone 4A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report