What Climate Zone is Moore, Texas?

Moore is in IECC Climate Zone 4B (Mixed - Dry). Get accurate Manual J load calculations with official design temperatures for Moore.

Climate Zone
4B
Winter Design
3°F
Summer Design
92°F
ZIP Codes
4

Moore, Texas falls within IECC Climate Zone 4B (Mixed - Dry), a mixed-climate region with dry moisture conditions. HVAC contractors working in Moore must use the official ASHRAE design temperatures of 3°F (99% winter) and 92°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4B experiences both significant heating and cooling loads. Moore homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Moore Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4B in Moore, Texas.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Moore HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4B requires precise load calculations. Upload your Moore blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Moore's exact design temperatures (3°F winter / 92°F summer).

Claim Free Report
No credit card required

Verify Your Moore ZIP Code

Enter your ZIP code to confirm it's in Moore and get climate zone details.

Moore covers 4 ZIP codes: 79013, 79029, 79086, 79105

Moore Design Temperatures

Official ASHRAE design temperatures for Moore, used for accurate Manual J load calculations.

Winter 99% Design Temp
3°F
Summer 1% Design Temp
92°F
Summer Wet Bulb
62°F

IECC Requirements for Zone 4B

Minimum insulation and window requirements for Moore per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Moore

Heating Systems

Gas furnace (92%+ AFUE)
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Moore

Upload your Moore blueprint and get a professional Manual J load calculation using official Zone 4B design temperatures. First report is FREE.

Moore design temps
Zone 4B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Moore contractors who trust AutoHVAC