What Climate Zone is Osage, Oklahoma?

Osage is in IECC Climate Zone 3A (Warm - Humid). Get accurate Manual J load calculations with official design temperatures for Osage.

Climate Zone
3A
Winter Design
22°F
Summer Design
94°F
ZIP Codes
12

Osage, Oklahoma falls within IECC Climate Zone 3A (Warm - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Osage must use the official ASHRAE design temperatures of 22°F (99% winter) and 94°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3A experiences both significant heating and cooling loads. Osage homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Osage Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3A in Osage, Oklahoma.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Osage HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3A requires precise load calculations. Upload your Osage blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Osage's exact design temperatures (22°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your Osage ZIP Code

Enter your ZIP code to confirm it's in Osage and get climate zone details.

Osage covers 12 ZIP codes: 74001, 74002, 74003, 74035, 74054, 74056, 74060, 74070, 74084, 74633 and 2 more

Osage Design Temperatures

Official ASHRAE design temperatures for Osage, used for accurate Manual J load calculations.

Winter 99% Design Temp
22°F
Summer 1% Design Temp
94°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 3A

Minimum insulation and window requirements for Osage per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Osage

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Osage

Upload your Osage blueprint and get a professional Manual J load calculation using official Zone 3A design temperatures. First report is FREE.

Osage design temps
Zone 3A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report