What Climate Zone is Comanche, Oklahoma?

Comanche is in IECC Climate Zone 3A (Warm - Humid). Get accurate Manual J load calculations with official design temperatures for Comanche.

Climate Zone
3A
Winter Design
22°F
Summer Design
94°F
ZIP Codes
15

Comanche, Oklahoma falls within IECC Climate Zone 3A (Warm - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Comanche must use the official ASHRAE design temperatures of 22°F (99% winter) and 94°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3A experiences both significant heating and cooling loads. Comanche homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Comanche Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3A in Comanche, Oklahoma.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Comanche HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3A requires precise load calculations. Upload your Comanche blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Comanche's exact design temperatures (22°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your Comanche ZIP Code

Enter your ZIP code to confirm it's in Comanche and get climate zone details.

Comanche covers 15 ZIP codes: 73501, 73503, 73505, 73507, 73527, 73538, 73540, 73541, 73543, 73552 and 5 more

Comanche Design Temperatures

Official ASHRAE design temperatures for Comanche, used for accurate Manual J load calculations.

Winter 99% Design Temp
22°F
Summer 1% Design Temp
94°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 3A

Minimum insulation and window requirements for Comanche per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Comanche

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Comanche

Upload your Comanche blueprint and get a professional Manual J load calculation using official Zone 3A design temperatures. First report is FREE.

Comanche design temps
Zone 3A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Comanche contractors who trust AutoHVAC