What Climate Zone is Vernon, Louisiana?

Vernon is in IECC Climate Zone 3A (Warm - Humid). Get accurate Manual J load calculations with official design temperatures for Vernon.

Climate Zone
3A
Winter Design
22°F
Summer Design
94°F
ZIP Codes
12

Vernon, Louisiana falls within IECC Climate Zone 3A (Warm - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Vernon must use the official ASHRAE design temperatures of 22°F (99% winter) and 94°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3A experiences both significant heating and cooling loads. Vernon homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Vernon Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3A in Vernon, Louisiana.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Vernon HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3A requires precise load calculations. Upload your Vernon blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Vernon's exact design temperatures (22°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your Vernon ZIP Code

Enter your ZIP code to confirm it's in Vernon and get climate zone details.

Vernon covers 12 ZIP codes: 70639, 70656, 70659, 71403, 71439, 71443, 71446, 71459, 71461, 71474 and 2 more

Vernon Design Temperatures

Official ASHRAE design temperatures for Vernon, used for accurate Manual J load calculations.

Winter 99% Design Temp
22°F
Summer 1% Design Temp
94°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 3A

Minimum insulation and window requirements for Vernon per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2015 IECC

Recommended HVAC Equipment for Vernon

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Vernon

Upload your Vernon blueprint and get a professional Manual J load calculation using official Zone 3A design temperatures. First report is FREE.

Vernon design temps
Zone 3A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Vernon contractors who trust AutoHVAC