What Climate Zone is Las Animas, Colorado?

Las Animas is in IECC Climate Zone 4B (Mixed - Dry). Get accurate Manual J load calculations with official design temperatures for Las Animas.

Climate Zone
4B
Winter Design
3°F
Summer Design
92°F
ZIP Codes
9

Las Animas, Colorado falls within IECC Climate Zone 4B (Mixed - Dry), a mixed-climate region with dry moisture conditions. HVAC contractors working in Las Animas must use the official ASHRAE design temperatures of 3°F (99% winter) and 92°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4B experiences both significant heating and cooling loads. Las Animas homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Las Animas Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4B in Las Animas, Colorado.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Las Animas HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4B requires precise load calculations. Upload your Las Animas blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Las Animas's exact design temperatures (3°F winter / 92°F summer).

Claim Free Report
No credit card required

Verify Your Las Animas ZIP Code

Enter your ZIP code to confirm it's in Las Animas and get climate zone details.

Las Animas covers 9 ZIP codes: 81020, 81024, 81027, 81049, 81059, 81081, 81082, 81091, 81046

Las Animas Design Temperatures

Official ASHRAE design temperatures for Las Animas, used for accurate Manual J load calculations.

Winter 99% Design Temp
3°F
Summer 1% Design Temp
92°F
Summer Wet Bulb
62°F

IECC Requirements for Zone 4B

Minimum insulation and window requirements for Las Animas per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Las Animas

Heating Systems

Gas furnace (92%+ AFUE)
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Las Animas

Upload your Las Animas blueprint and get a professional Manual J load calculation using official Zone 4B design temperatures. First report is FREE.

Las Animas design temps
Zone 4B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Las Animas contractors who trust AutoHVAC