What Climate Zone is Clear Creek, Colorado?

Clear Creek is in IECC Climate Zone 7 (Very Cold). Get accurate Manual J load calculations with official design temperatures for Clear Creek.

Climate Zone
7
Winter Design
-18°F
Summer Design
87°F
ZIP Codes
5

Clear Creek, Colorado falls within IECC Climate Zone 7 (Very Cold), a heating-dominated region with moist moisture conditions. HVAC contractors working in Clear Creek must use the official ASHRAE design temperatures of -18°F (99% winter) and 87°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 7 is heating-dominated, insulation levels are critical. Clear Creek homes require a minimum of R-20 wall insulation, R-60 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Clear Creek Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 7 in Clear Creek, Colorado.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-60R-value
Wall InsulationR-20R-value
Floor InsulationR-38R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.45Coefficient
Air Infiltration0.15ACH50

Clear Creek HVAC Contractors: Get Your Free Manual J Report

Climate Zone 7 requires precise load calculations. Upload your Clear Creek blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Clear Creek's exact design temperatures (-18°F winter / 87°F summer).

Claim Free Report
No credit card required

Verify Your Clear Creek ZIP Code

Enter your ZIP code to confirm it's in Clear Creek and get climate zone details.

Clear Creek covers 5 ZIP codes: 80436, 80438, 80444, 80452, 80476

Clear Creek Design Temperatures

Official ASHRAE design temperatures for Clear Creek, used for accurate Manual J load calculations.

Winter 99% Design Temp
-18°F
Summer 1% Design Temp
87°F
Summer Wet Bulb
70°F

IECC Requirements for Zone 7

Minimum insulation and window requirements for Clear Creek per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-60
Floor Insulation:R-38
Window U-Factor:0.3
Window SHGC:0.45

Energy Code: 2021 IECC

Recommended HVAC Equipment for Clear Creek

Heating Systems

Gas furnace (97%+ AFUE)
Boiler
Cold climate heat pump with backup
Typical AFUE
97-98.5%

Cooling Systems

AC (minimal, 13 SEER)
Typical SEER
13 SEER