What Climate Zone is Adams, Colorado?

Adams is in IECC Climate Zone 5B (Cool - Dry). Get accurate Manual J load calculations with official design temperatures for Adams.

Climate Zone
5B
Winter Design
-7°F
Summer Design
91°F
ZIP Codes
19

Adams, Colorado falls within IECC Climate Zone 5B (Cool - Dry), a heating-dominated region with dry moisture conditions. HVAC contractors working in Adams must use the official ASHRAE design temperatures of -7°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 5B is heating-dominated, insulation levels are critical. Adams homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Adams Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 5B in Adams, Colorado.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Adams HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5B requires precise load calculations. Upload your Adams blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Adams's exact design temperatures (-7°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Adams ZIP Code

Enter your ZIP code to confirm it's in Adams and get climate zone details.

Adams covers 19 ZIP codes: 80019, 80022, 80024, 80030, 80031, 80102, 80136, 80221, 80229, 80233 and 9 more

Adams Design Temperatures

Official ASHRAE design temperatures for Adams, used for accurate Manual J load calculations.

Winter 99% Design Temp
-7°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
63°F

IECC Requirements for Zone 5B

Minimum insulation and window requirements for Adams per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Adams

Heating Systems

Gas furnace (95%+ AFUE)
Typical AFUE
95-98%

Cooling Systems

AC (13-15 SEER)
Typical SEER
13-15 SEER

Get Free Manual J Calculations for Adams

Upload your Adams blueprint and get a professional Manual J load calculation using official Zone 5B design temperatures. First report is FREE.

Adams design temps
Zone 5B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report