What Climate Zone is Logan, Arkansas?

Logan is in IECC Climate Zone 3A (Warm - Humid). Get accurate Manual J load calculations with official design temperatures for Logan.

Climate Zone
3A
Winter Design
22°F
Summer Design
94°F
ZIP Codes
9

Logan, Arkansas falls within IECC Climate Zone 3A (Warm - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Logan must use the official ASHRAE design temperatures of 22°F (99% winter) and 94°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3A experiences both significant heating and cooling loads. Logan homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Logan Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3A in Logan, Arkansas.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Logan HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3A requires precise load calculations. Upload your Logan blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Logan's exact design temperatures (22°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your Logan ZIP Code

Enter your ZIP code to confirm it's in Logan and get climate zone details.

Logan covers 9 ZIP codes: 72826, 72835, 72851, 72855, 72863, 72865, 72927, 72943, 72951

Logan Design Temperatures

Official ASHRAE design temperatures for Logan, used for accurate Manual J load calculations.

Winter 99% Design Temp
22°F
Summer 1% Design Temp
94°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 3A

Minimum insulation and window requirements for Logan per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Logan

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Logan

Upload your Logan blueprint and get a professional Manual J load calculation using official Zone 3A design temperatures. First report is FREE.

Logan design temps
Zone 3A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Logan contractors who trust AutoHVAC