What Climate Zone is Russell, Alabama?

Russell is in IECC Climate Zone 3A (Warm - Humid). Get accurate Manual J load calculations with official design temperatures for Russell.

Climate Zone
3A
Winter Design
22°F
Summer Design
94°F
ZIP Codes
10

Russell, Alabama falls within IECC Climate Zone 3A (Warm - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Russell must use the official ASHRAE design temperatures of 22°F (99% winter) and 94°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3A experiences both significant heating and cooling loads. Russell homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Russell Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3A in Russell, Alabama.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Russell HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3A requires precise load calculations. Upload your Russell blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Russell's exact design temperatures (22°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your Russell ZIP Code

Enter your ZIP code to confirm it's in Russell and get climate zone details.

Russell covers 10 ZIP codes: 36856, 36858, 36860, 36867, 36869, 36871, 36875, 36851, 36859, 36868

Russell Design Temperatures

Official ASHRAE design temperatures for Russell, used for accurate Manual J load calculations.

Winter 99% Design Temp
22°F
Summer 1% Design Temp
94°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 3A

Minimum insulation and window requirements for Russell per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2018 IECC

Recommended HVAC Equipment for Russell

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER