What Climate Zone is Etowah, Alabama?

Etowah is in IECC Climate Zone 3A (Warm - Humid). Get accurate Manual J load calculations with official design temperatures for Etowah.

Climate Zone
3A
Winter Design
22°F
Summer Design
94°F
ZIP Codes
12

Etowah, Alabama falls within IECC Climate Zone 3A (Warm - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Etowah must use the official ASHRAE design temperatures of 22°F (99% winter) and 94°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3A experiences both significant heating and cooling loads. Etowah homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Etowah Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3A in Etowah, Alabama.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Etowah HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3A requires precise load calculations. Upload your Etowah blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Etowah's exact design temperatures (22°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your Etowah ZIP Code

Enter your ZIP code to confirm it's in Etowah and get climate zone details.

Etowah covers 12 ZIP codes: 35901, 35903, 35904, 35905, 35906, 35907, 35952, 35954, 35956, 35972 and 2 more

Etowah Design Temperatures

Official ASHRAE design temperatures for Etowah, used for accurate Manual J load calculations.

Winter 99% Design Temp
22°F
Summer 1% Design Temp
94°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 3A

Minimum insulation and window requirements for Etowah per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2018 IECC

Recommended HVAC Equipment for Etowah

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Etowah

Upload your Etowah blueprint and get a professional Manual J load calculation using official Zone 3A design temperatures. First report is FREE.

Etowah design temps
Zone 3A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Etowah contractors who trust AutoHVAC