What Climate Zone is Cullman, Alabama?

Cullman is in IECC Climate Zone 3A (Warm - Humid). Get accurate Manual J load calculations with official design temperatures for Cullman.

Climate Zone
3A
Winter Design
22°F
Summer Design
94°F
ZIP Codes
13

Cullman, Alabama falls within IECC Climate Zone 3A (Warm - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Cullman must use the official ASHRAE design temperatures of 22°F (99% winter) and 94°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3A experiences both significant heating and cooling loads. Cullman homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Cullman Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3A in Cullman, Alabama.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Cullman HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3A requires precise load calculations. Upload your Cullman blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Cullman's exact design temperatures (22°F winter / 94°F summer).

Claim Free Report
No credit card required

Verify Your Cullman ZIP Code

Enter your ZIP code to confirm it's in Cullman and get climate zone details.

Cullman covers 13 ZIP codes: 35019, 35033, 35053, 35055, 35057, 35058, 35070, 35077, 35083, 35087 and 3 more

Cullman Design Temperatures

Official ASHRAE design temperatures for Cullman, used for accurate Manual J load calculations.

Winter 99% Design Temp
22°F
Summer 1% Design Temp
94°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 3A

Minimum insulation and window requirements for Cullman per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2018 IECC

Recommended HVAC Equipment for Cullman

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Cullman

Upload your Cullman blueprint and get a professional Manual J load calculation using official Zone 3A design temperatures. First report is FREE.

Cullman design temps
Zone 3A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Cullman contractors who trust AutoHVAC