What Climate Zone is Thurston, Washington?

Thurston is in IECC Climate Zone 4C (Mixed - Marine). Get accurate Manual J load calculations with official design temperatures for Thurston.

Climate Zone
4C
Winter Design
29°F
Summer Design
85°F
ZIP Codes
22

Thurston, Washington falls within IECC Climate Zone 4C (Mixed - Marine), a mixed-climate region with marine moisture conditions. HVAC contractors working in Thurston must use the official ASHRAE design temperatures of 29°F (99% winter) and 85°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4C experiences both significant heating and cooling loads. Thurston homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Thurston Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4C in Thurston, Washington.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Thurston HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4C requires precise load calculations. Upload your Thurston blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Thurston's exact design temperatures (29°F winter / 85°F summer).

Claim Free Report
No credit card required

Verify Your Thurston ZIP Code

Enter your ZIP code to confirm it's in Thurston and get climate zone details.

Thurston covers 22 ZIP codes: 98501, 98502, 98503, 98506, 98512, 98513, 98516, 98530, 98576, 98579 and 12 more

Thurston Design Temperatures

Official ASHRAE design temperatures for Thurston, used for accurate Manual J load calculations.

Winter 99% Design Temp
29°F
Summer 1% Design Temp
85°F
Summer Wet Bulb
67°F

IECC Requirements for Zone 4C

Minimum insulation and window requirements for Thurston per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Thurston

Heating Systems

Gas furnace
Heat pump
Typical AFUE
92-95%

Cooling Systems

AC (optional)
Heat pump
Typical SEER
14 SEER

Get Free Manual J Calculations for Thurston

Upload your Thurston blueprint and get a professional Manual J load calculation using official Zone 4C design temperatures. First report is FREE.

Thurston design temps
Zone 4C compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Thurston contractors who trust AutoHVAC