What Climate Zone is Okanogan, Washington?

Okanogan is in IECC Climate Zone 6B (Cold - Dry). Get accurate Manual J load calculations with official design temperatures for Okanogan.

Climate Zone
6B
Winter Design
-13°F
Summer Design
91°F
ZIP Codes
18

Okanogan, Washington falls within IECC Climate Zone 6B (Cold - Dry), a heating-dominated region with dry moisture conditions. HVAC contractors working in Okanogan must use the official ASHRAE design temperatures of -13°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 6B is heating-dominated, insulation levels are critical. Okanogan homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Okanogan Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 6B in Okanogan, Washington.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Okanogan HVAC Contractors: Get Your Free Manual J Report

Climate Zone 6B requires precise load calculations. Upload your Okanogan blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Okanogan's exact design temperatures (-13°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Okanogan ZIP Code

Enter your ZIP code to confirm it's in Okanogan and get climate zone details.

Okanogan covers 18 ZIP codes: 98812, 98814, 98819, 98827, 98829, 98833, 98834, 98840, 98841, 98844 and 8 more

Okanogan Design Temperatures

Official ASHRAE design temperatures for Okanogan, used for accurate Manual J load calculations.

Winter 99% Design Temp
-13°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
62°F

IECC Requirements for Zone 6B

Minimum insulation and window requirements for Okanogan per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Okanogan

Heating Systems

Gas furnace (96%+ AFUE)
Boiler
Typical AFUE
96-98%

Cooling Systems

AC (13-14 SEER, often optional)
Typical SEER
13-14 SEER

Get Free Manual J Calculations for Okanogan

Upload your Okanogan blueprint and get a professional Manual J load calculation using official Zone 6B design temperatures. First report is FREE.

Okanogan design temps
Zone 6B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report