What Climate Zone is Rutland, Vermont?

Rutland is in IECC Climate Zone 6A (Cold - Humid). Get accurate Manual J load calculations with official design temperatures for Rutland.

Climate Zone
6A
Winter Design
-9°F
Summer Design
89°F
ZIP Codes
30

Rutland, Vermont falls within IECC Climate Zone 6A (Cold - Humid), a heating-dominated region with humid moisture conditions. HVAC contractors working in Rutland must use the official ASHRAE design temperatures of -9°F (99% winter) and 89°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 6A is heating-dominated, insulation levels are critical. Rutland homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Rutland Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 6A in Rutland, Vermont.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Rutland HVAC Contractors: Get Your Free Manual J Report

Climate Zone 6A requires precise load calculations. Upload your Rutland blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Rutland's exact design temperatures (-9°F winter / 89°F summer).

Claim Free Report
No credit card required

Verify Your Rutland ZIP Code

Enter your ZIP code to confirm it's in Rutland and get climate zone details.

Rutland covers 30 ZIP codes: 05701, 05730, 05732, 05733, 05735, 05736, 05737, 05738, 05739, 05742 and 20 more

Rutland Design Temperatures

Official ASHRAE design temperatures for Rutland, used for accurate Manual J load calculations.

Winter 99% Design Temp
-9°F
Summer 1% Design Temp
89°F
Summer Wet Bulb
73°F

IECC Requirements for Zone 6A

Minimum insulation and window requirements for Rutland per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Rutland

Heating Systems

Gas furnace (96%+ AFUE)
Boiler
Cold climate heat pump
Typical AFUE
96-98%

Cooling Systems

AC (13-15 SEER)
Typical SEER
13-15 SEER

Get Free Manual J Calculations for Rutland

Upload your Rutland blueprint and get a professional Manual J load calculation using official Zone 6A design temperatures. First report is FREE.

Rutland design temps
Zone 6A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report