What Climate Zone is Millard, Utah?

Millard is in IECC Climate Zone 5B (Cool - Dry). Get accurate Manual J load calculations with official design temperatures for Millard.

Climate Zone
5B
Winter Design
-7°F
Summer Design
91°F
ZIP Codes
11

Millard, Utah falls within IECC Climate Zone 5B (Cool - Dry), a heating-dominated region with dry moisture conditions. HVAC contractors working in Millard must use the official ASHRAE design temperatures of -7°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 5B is heating-dominated, insulation levels are critical. Millard homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Millard Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 5B in Millard, Utah.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Millard HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5B requires precise load calculations. Upload your Millard blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Millard's exact design temperatures (-7°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Millard ZIP Code

Enter your ZIP code to confirm it's in Millard and get climate zone details.

Millard covers 11 ZIP codes: 84624, 84631, 84635, 84636, 84637, 84638, 84640, 84649, 84656, 84728 and 1 more

Millard Design Temperatures

Official ASHRAE design temperatures for Millard, used for accurate Manual J load calculations.

Winter 99% Design Temp
-7°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
63°F

IECC Requirements for Zone 5B

Minimum insulation and window requirements for Millard per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Millard

Heating Systems

Gas furnace (95%+ AFUE)
Typical AFUE
95-98%

Cooling Systems

AC (13-15 SEER)
Typical SEER
13-15 SEER