What Climate Zone is Uvalde, Texas?

Uvalde is in IECC Climate Zone 2B (Hot - Dry). Get accurate Manual J load calculations with official design temperatures for Uvalde.

Climate Zone
2B
Winter Design
31°F
Summer Design
108°F
ZIP Codes
6

Uvalde, Texas falls within IECC Climate Zone 2B (Hot - Dry), a cooling-dominated region with dry moisture conditions. HVAC contractors working in Uvalde must use the official ASHRAE design temperatures of 31°F (99% winter) and 108°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2B is cooling-dominated, solar heat gain control is critical. Uvalde homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

Uvalde Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2B in Uvalde, Texas.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Uvalde HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2B requires precise load calculations. Upload your Uvalde blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Uvalde's exact design temperatures (31°F winter / 108°F summer).

Claim Free Report
No credit card required

Verify Your Uvalde ZIP Code

Enter your ZIP code to confirm it's in Uvalde and get climate zone details.

Uvalde covers 6 ZIP codes: 78801, 78838, 78870, 78881, 78884, 78802

Uvalde Design Temperatures

Official ASHRAE design temperatures for Uvalde, used for accurate Manual J load calculations.

Winter 99% Design Temp
31°F
Summer 1% Design Temp
108°F
Summer Wet Bulb
71°F

IECC Requirements for Zone 2B

Minimum insulation and window requirements for Uvalde per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Uvalde

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-90%

Cooling Systems

AC (14-16 SEER)
Evaporative cooling (swamp cooler)
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Uvalde

Upload your Uvalde blueprint and get a professional Manual J load calculation using official Zone 2B design temperatures. First report is FREE.

Uvalde design temps
Zone 2B compliant
Ready in 60 seconds