What Climate Zone is Potter, Texas?

Potter is in IECC Climate Zone 4B (Mixed - Dry). Get accurate Manual J load calculations with official design temperatures for Potter.

Climate Zone
4B
Winter Design
3°F
Summer Design
92°F
ZIP Codes
24

Potter, Texas falls within IECC Climate Zone 4B (Mixed - Dry), a mixed-climate region with dry moisture conditions. HVAC contractors working in Potter must use the official ASHRAE design temperatures of 3°F (99% winter) and 92°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4B experiences both significant heating and cooling loads. Potter homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Potter Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4B in Potter, Texas.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Potter HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4B requires precise load calculations. Upload your Potter blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Potter's exact design temperatures (3°F winter / 92°F summer).

Claim Free Report
No credit card required

Verify Your Potter ZIP Code

Enter your ZIP code to confirm it's in Potter and get climate zone details.

Potter covers 24 ZIP codes: 79012, 79101, 79102, 79103, 79104, 79106, 79107, 79108, 79111, 79124 and 14 more

Potter Design Temperatures

Official ASHRAE design temperatures for Potter, used for accurate Manual J load calculations.

Winter 99% Design Temp
3°F
Summer 1% Design Temp
92°F
Summer Wet Bulb
62°F

IECC Requirements for Zone 4B

Minimum insulation and window requirements for Potter per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Potter

Heating Systems

Gas furnace (92%+ AFUE)
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Potter

Upload your Potter blueprint and get a professional Manual J load calculation using official Zone 4B design temperatures. First report is FREE.

Potter design temps
Zone 4B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Potter contractors who trust AutoHVAC