What Climate Zone is Montgomery, Texas?

Montgomery is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official design temperatures for Montgomery.

Climate Zone
2A
Winter Design
32°F
Summer Design
95°F
ZIP Codes
24

Montgomery, Texas falls within IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. HVAC contractors working in Montgomery must use the official ASHRAE design temperatures of 32°F (99% winter) and 95°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2A is cooling-dominated, solar heat gain control is critical. Montgomery homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

Montgomery Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2A in Montgomery, Texas.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Montgomery HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your Montgomery blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Montgomery's exact design temperatures (32°F winter / 95°F summer).

Claim Free Report
No credit card required

Verify Your Montgomery ZIP Code

Enter your ZIP code to confirm it's in Montgomery and get climate zone details.

Montgomery covers 24 ZIP codes: 77301, 77302, 77303, 77304, 77306, 77316, 77318, 77333, 77354, 77355 and 14 more

Montgomery Design Temperatures

Official ASHRAE design temperatures for Montgomery, used for accurate Manual J load calculations.

Winter 99% Design Temp
32°F
Summer 1% Design Temp
95°F
Summer Wet Bulb
77°F

IECC Requirements for Zone 2A

Minimum insulation and window requirements for Montgomery per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Montgomery

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Montgomery

Upload your Montgomery blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

Montgomery design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report