What Climate Zone is Midland, Texas?

Midland is in IECC Climate Zone 3B (Warm - Dry). Get accurate Manual J load calculations with official design temperatures for Midland.

Climate Zone
3B
Winter Design
35°F
Summer Design
99°F
ZIP Codes
11

Midland, Texas falls within IECC Climate Zone 3B (Warm - Dry), a mixed-climate region with dry moisture conditions. HVAC contractors working in Midland must use the official ASHRAE design temperatures of 35°F (99% winter) and 99°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3B experiences both significant heating and cooling loads. Midland homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Midland Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3B in Midland, Texas.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Midland HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3B requires precise load calculations. Upload your Midland blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Midland's exact design temperatures (35°F winter / 99°F summer).

Claim Free Report
No credit card required

Verify Your Midland ZIP Code

Enter your ZIP code to confirm it's in Midland and get climate zone details.

Midland covers 11 ZIP codes: 79701, 79703, 79705, 79706, 79707, 79702, 79704, 79708, 79710, 79711 and 1 more

Midland Design Temperatures

Official ASHRAE design temperatures for Midland, used for accurate Manual J load calculations.

Winter 99% Design Temp
35°F
Summer 1% Design Temp
99°F
Summer Wet Bulb
68°F

IECC Requirements for Zone 3B

Minimum insulation and window requirements for Midland per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Midland

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Typical SEER
14-16 SEER