What Climate Zone is Carroll, Tennessee?

Carroll is in IECC Climate Zone 4A (Mixed - Humid). Get accurate Manual J load calculations with official design temperatures for Carroll.

Climate Zone
4A
Winter Design
13°F
Summer Design
91°F
ZIP Codes
13

Carroll, Tennessee falls within IECC Climate Zone 4A (Mixed - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Carroll must use the official ASHRAE design temperatures of 13°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4A experiences both significant heating and cooling loads. Carroll homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Carroll Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4A in Carroll, Tennessee.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Carroll HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4A requires precise load calculations. Upload your Carroll blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Carroll's exact design temperatures (13°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Carroll ZIP Code

Enter your ZIP code to confirm it's in Carroll and get climate zone details.

Carroll covers 13 ZIP codes: 38201, 38220, 38235, 38258, 38317, 38318, 38321, 38342, 38344, 38348 and 3 more

Carroll Design Temperatures

Official ASHRAE design temperatures for Carroll, used for accurate Manual J load calculations.

Winter 99% Design Temp
13°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 4A

Minimum insulation and window requirements for Carroll per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Carroll

Heating Systems

Gas furnace (90%+ AFUE)
Heat pump
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Carroll

Upload your Carroll blueprint and get a professional Manual J load calculation using official Zone 4A design temperatures. First report is FREE.

Carroll design temps
Zone 4A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report