What Climate Zone is Deschutes, Oregon?

Deschutes is in IECC Climate Zone 5B (Cool - Dry). Get accurate Manual J load calculations with official design temperatures for Deschutes.

Climate Zone
5B
Winter Design
-7°F
Summer Design
91°F
ZIP Codes
10

Deschutes, Oregon falls within IECC Climate Zone 5B (Cool - Dry), a heating-dominated region with dry moisture conditions. HVAC contractors working in Deschutes must use the official ASHRAE design temperatures of -7°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 5B is heating-dominated, insulation levels are critical. Deschutes homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Deschutes Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 5B in Deschutes, Oregon.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Deschutes HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5B requires precise load calculations. Upload your Deschutes blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Deschutes's exact design temperatures (-7°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Deschutes ZIP Code

Enter your ZIP code to confirm it's in Deschutes and get climate zone details.

Deschutes covers 10 ZIP codes: 97701, 97702, 97707, 97712, 97739, 97756, 97759, 97703, 97708, 97709

Deschutes Design Temperatures

Official ASHRAE design temperatures for Deschutes, used for accurate Manual J load calculations.

Winter 99% Design Temp
-7°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
63°F

IECC Requirements for Zone 5B

Minimum insulation and window requirements for Deschutes per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Deschutes

Heating Systems

Gas furnace (95%+ AFUE)
Typical AFUE
95-98%

Cooling Systems

AC (13-15 SEER)
Typical SEER
13-15 SEER