What Climate Zone is Cimarron, Oklahoma?

Cimarron is in IECC Climate Zone 4B (Mixed - Dry). Get accurate Manual J load calculations with official design temperatures for Cimarron.

Climate Zone
4B
Winter Design
3°F
Summer Design
92°F
ZIP Codes
4

Cimarron, Oklahoma falls within IECC Climate Zone 4B (Mixed - Dry), a mixed-climate region with dry moisture conditions. HVAC contractors working in Cimarron must use the official ASHRAE design temperatures of 3°F (99% winter) and 92°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4B experiences both significant heating and cooling loads. Cimarron homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Cimarron Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4B in Cimarron, Oklahoma.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Cimarron HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4B requires precise load calculations. Upload your Cimarron blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Cimarron's exact design temperatures (3°F winter / 92°F summer).

Claim Free Report
No credit card required

Verify Your Cimarron ZIP Code

Enter your ZIP code to confirm it's in Cimarron and get climate zone details.

Cimarron covers 4 ZIP codes: 73933, 73937, 73946, 73947

Cimarron Design Temperatures

Official ASHRAE design temperatures for Cimarron, used for accurate Manual J load calculations.

Winter 99% Design Temp
3°F
Summer 1% Design Temp
92°F
Summer Wet Bulb
62°F

IECC Requirements for Zone 4B

Minimum insulation and window requirements for Cimarron per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Cimarron

Heating Systems

Gas furnace (92%+ AFUE)
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Cimarron

Upload your Cimarron blueprint and get a professional Manual J load calculation using official Zone 4B design temperatures. First report is FREE.

Cimarron design temps
Zone 4B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report