What Climate Zone is Van Wert, Ohio?

Van Wert is in IECC Climate Zone 5A (Cool - Humid). Get accurate Manual J load calculations with official design temperatures for Van Wert.

Climate Zone
5A
Winter Design
0°F
Summer Design
91°F
ZIP Codes
9

Van Wert, Ohio falls within IECC Climate Zone 5A (Cool - Humid), a heating-dominated region with humid moisture conditions. HVAC contractors working in Van Wert must use the official ASHRAE design temperatures of 0°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 5A is heating-dominated, insulation levels are critical. Van Wert homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Van Wert Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 5A in Van Wert, Ohio.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Van Wert HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5A requires precise load calculations. Upload your Van Wert blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Van Wert's exact design temperatures (0°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Van Wert ZIP Code

Enter your ZIP code to confirm it's in Van Wert and get climate zone details.

Van Wert covers 9 ZIP codes: 45832, 45838, 45863, 45874, 45886, 45891, 45894, 45898, 45899

Van Wert Design Temperatures

Official ASHRAE design temperatures for Van Wert, used for accurate Manual J load calculations.

Winter 99% Design Temp
0°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 5A

Minimum insulation and window requirements for Van Wert per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Van Wert

Heating Systems

Gas furnace (95%+ AFUE)
Boiler
Heat pump (cold climate)
Typical AFUE
95-98%

Cooling Systems

AC (13-16 SEER)
Heat pump
Typical SEER
13-16 SEER

Get Free Manual J Calculations for Van Wert

Upload your Van Wert blueprint and get a professional Manual J load calculation using official Zone 5A design temperatures. First report is FREE.

Van Wert design temps
Zone 5A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Van Wert contractors who trust AutoHVAC