What Climate Zone is Custer, Nebraska?

Custer is in IECC Climate Zone 5A (Cool - Humid). Get accurate Manual J load calculations with official design temperatures for Custer.

Climate Zone
5A
Winter Design
0°F
Summer Design
91°F
ZIP Codes
11

Custer, Nebraska falls within IECC Climate Zone 5A (Cool - Humid), a heating-dominated region with humid moisture conditions. HVAC contractors working in Custer must use the official ASHRAE design temperatures of 0°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 5A is heating-dominated, insulation levels are critical. Custer homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Custer Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 5A in Custer, Nebraska.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Custer HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5A requires precise load calculations. Upload your Custer blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Custer's exact design temperatures (0°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Custer ZIP Code

Enter your ZIP code to confirm it's in Custer and get climate zone details.

Custer covers 11 ZIP codes: 68813, 68814, 68822, 68825, 68828, 68855, 68856, 68860, 68874, 68881 and 1 more

Custer Design Temperatures

Official ASHRAE design temperatures for Custer, used for accurate Manual J load calculations.

Winter 99% Design Temp
0°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 5A

Minimum insulation and window requirements for Custer per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Custer

Heating Systems

Gas furnace (95%+ AFUE)
Boiler
Heat pump (cold climate)
Typical AFUE
95-98%

Cooling Systems

AC (13-16 SEER)
Heat pump
Typical SEER
13-16 SEER

Get Free Manual J Calculations for Custer

Upload your Custer blueprint and get a professional Manual J load calculation using official Zone 5A design temperatures. First report is FREE.

Custer design temps
Zone 5A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Custer contractors who trust AutoHVAC