What Climate Zone is Lenawee, Michigan?

Lenawee is in IECC Climate Zone 5A (Cool - Humid). Get accurate Manual J load calculations with official design temperatures for Lenawee.

Climate Zone
5A
Winter Design
0°F
Summer Design
91°F
ZIP Codes
18

Lenawee, Michigan falls within IECC Climate Zone 5A (Cool - Humid), a heating-dominated region with humid moisture conditions. HVAC contractors working in Lenawee must use the official ASHRAE design temperatures of 0°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 5A is heating-dominated, insulation levels are critical. Lenawee homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Lenawee Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 5A in Lenawee, Michigan.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Lenawee HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5A requires precise load calculations. Upload your Lenawee blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Lenawee's exact design temperatures (0°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Lenawee ZIP Code

Enter your ZIP code to confirm it's in Lenawee and get climate zone details.

Lenawee covers 18 ZIP codes: 49220, 49221, 49228, 49229, 49235, 49236, 49238, 49247, 49248, 49253 and 8 more

Lenawee Design Temperatures

Official ASHRAE design temperatures for Lenawee, used for accurate Manual J load calculations.

Winter 99% Design Temp
0°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 5A

Minimum insulation and window requirements for Lenawee per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2020 IECC

Recommended HVAC Equipment for Lenawee

Heating Systems

Gas furnace (95%+ AFUE)
Boiler
Heat pump (cold climate)
Typical AFUE
95-98%

Cooling Systems

AC (13-16 SEER)
Heat pump
Typical SEER
13-16 SEER

Get Free Manual J Calculations for Lenawee

Upload your Lenawee blueprint and get a professional Manual J load calculation using official Zone 5A design temperatures. First report is FREE.

Lenawee design temps
Zone 5A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Lenawee contractors who trust AutoHVAC