What Climate Zone is Leelanau, Michigan?

Leelanau is in IECC Climate Zone 6A (Cold - Humid). Get accurate Manual J load calculations with official design temperatures for Leelanau.

Climate Zone
6A
Winter Design
-9°F
Summer Design
89°F
ZIP Codes
9

Leelanau, Michigan falls within IECC Climate Zone 6A (Cold - Humid), a heating-dominated region with humid moisture conditions. HVAC contractors working in Leelanau must use the official ASHRAE design temperatures of -9°F (99% winter) and 89°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 6A is heating-dominated, insulation levels are critical. Leelanau homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Leelanau Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 6A in Leelanau, Michigan.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Leelanau HVAC Contractors: Get Your Free Manual J Report

Climate Zone 6A requires precise load calculations. Upload your Leelanau blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Leelanau's exact design temperatures (-9°F winter / 89°F summer).

Claim Free Report
No credit card required

Verify Your Leelanau ZIP Code

Enter your ZIP code to confirm it's in Leelanau and get climate zone details.

Leelanau covers 9 ZIP codes: 49621, 49630, 49636, 49653, 49654, 49664, 49670, 49682, 49674

Leelanau Design Temperatures

Official ASHRAE design temperatures for Leelanau, used for accurate Manual J load calculations.

Winter 99% Design Temp
-9°F
Summer 1% Design Temp
89°F
Summer Wet Bulb
73°F

IECC Requirements for Zone 6A

Minimum insulation and window requirements for Leelanau per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2020 IECC

Recommended HVAC Equipment for Leelanau

Heating Systems

Gas furnace (96%+ AFUE)
Boiler
Cold climate heat pump
Typical AFUE
96-98%

Cooling Systems

AC (13-15 SEER)
Typical SEER
13-15 SEER

Get Free Manual J Calculations for Leelanau

Upload your Leelanau blueprint and get a professional Manual J load calculation using official Zone 6A design temperatures. First report is FREE.

Leelanau design temps
Zone 6A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Leelanau contractors who trust AutoHVAC