What Climate Zone is Anne Arundel, Maryland?

Anne Arundel is in IECC Climate Zone 4A (Mixed - Humid). Get accurate Manual J load calculations with official design temperatures for Anne Arundel.

Climate Zone
4A
Winter Design
13°F
Summer Design
91°F
ZIP Codes
43

Anne Arundel, Maryland falls within IECC Climate Zone 4A (Mixed - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Anne Arundel must use the official ASHRAE design temperatures of 13°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4A experiences both significant heating and cooling loads. Anne Arundel homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Anne Arundel Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4A in Anne Arundel, Maryland.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Anne Arundel HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4A requires precise load calculations. Upload your Anne Arundel blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Anne Arundel's exact design temperatures (13°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Anne Arundel ZIP Code

Enter your ZIP code to confirm it's in Anne Arundel and get climate zone details.

Anne Arundel covers 43 ZIP codes: 20711, 20724, 20733, 20751, 20755, 20758, 20764, 20765, 20776, 20778 and 33 more

Anne Arundel Design Temperatures

Official ASHRAE design temperatures for Anne Arundel, used for accurate Manual J load calculations.

Winter 99% Design Temp
13°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 4A

Minimum insulation and window requirements for Anne Arundel per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Anne Arundel

Heating Systems

Gas furnace (90%+ AFUE)
Heat pump
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Anne Arundel

Upload your Anne Arundel blueprint and get a professional Manual J load calculation using official Zone 4A design temperatures. First report is FREE.

Anne Arundel design temps
Zone 4A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report