What Climate Zone is Allen, Indiana?

Allen is in IECC Climate Zone 5A (Cool - Humid). Get accurate Manual J load calculations with official design temperatures for Allen.

Climate Zone
5A
Winter Design
0°F
Summer Design
91°F
ZIP Codes
38

Allen, Indiana falls within IECC Climate Zone 5A (Cool - Humid), a heating-dominated region with humid moisture conditions. HVAC contractors working in Allen must use the official ASHRAE design temperatures of 0°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 5A is heating-dominated, insulation levels are critical. Allen homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Allen Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 5A in Allen, Indiana.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Allen HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5A requires precise load calculations. Upload your Allen blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Allen's exact design temperatures (0°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Allen ZIP Code

Enter your ZIP code to confirm it's in Allen and get climate zone details.

Allen covers 38 ZIP codes: 46741, 46743, 46745, 46748, 46765, 46773, 46774, 46788, 46797, 46798 and 28 more

Allen Design Temperatures

Official ASHRAE design temperatures for Allen, used for accurate Manual J load calculations.

Winter 99% Design Temp
0°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 5A

Minimum insulation and window requirements for Allen per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2020 IECC

Recommended HVAC Equipment for Allen

Heating Systems

Gas furnace (95%+ AFUE)
Boiler
Heat pump (cold climate)
Typical AFUE
95-98%

Cooling Systems

AC (13-16 SEER)
Heat pump
Typical SEER
13-16 SEER

Get Free Manual J Calculations for Allen

Upload your Allen blueprint and get a professional Manual J load calculation using official Zone 5A design temperatures. First report is FREE.

Allen design temps
Zone 5A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Allen contractors who trust AutoHVAC