What Climate Zone is Twin Falls, Idaho?

Twin Falls is in IECC Climate Zone 5B (Cool - Dry). Get accurate Manual J load calculations with official design temperatures for Twin Falls.

Climate Zone
5B
Winter Design
-7°F
Summer Design
91°F
ZIP Codes
9

Twin Falls, Idaho falls within IECC Climate Zone 5B (Cool - Dry), a heating-dominated region with dry moisture conditions. HVAC contractors working in Twin Falls must use the official ASHRAE design temperatures of -7°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 5B is heating-dominated, insulation levels are critical. Twin Falls homes require a minimum of R-20 wall insulation, R-49 ceiling insulation, and windows with a U-factor of 0.3 or lower per the IECC 2021 energy code.

Twin Falls Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 5B in Twin Falls, Idaho.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Twin Falls HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5B requires precise load calculations. Upload your Twin Falls blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Twin Falls's exact design temperatures (-7°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Twin Falls ZIP Code

Enter your ZIP code to confirm it's in Twin Falls and get climate zone details.

Twin Falls covers 9 ZIP codes: 83301, 83302, 83316, 83321, 83328, 83334, 83341, 83344, 83303

Twin Falls Design Temperatures

Official ASHRAE design temperatures for Twin Falls, used for accurate Manual J load calculations.

Winter 99% Design Temp
-7°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
63°F

IECC Requirements for Zone 5B

Minimum insulation and window requirements for Twin Falls per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Twin Falls

Heating Systems

Gas furnace (95%+ AFUE)
Typical AFUE
95-98%

Cooling Systems

AC (13-15 SEER)
Typical SEER
13-15 SEER

Get Free Manual J Calculations for Twin Falls

Upload your Twin Falls blueprint and get a professional Manual J load calculation using official Zone 5B design temperatures. First report is FREE.

Twin Falls design temps
Zone 5B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Twin Falls contractors who trust AutoHVAC