What Climate Zone is Jeff Davis, Georgia?

Jeff Davis is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official design temperatures for Jeff Davis.

Climate Zone
2A
Winter Design
32°F
Summer Design
95°F
ZIP Codes
2

Jeff Davis, Georgia falls within IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. HVAC contractors working in Jeff Davis must use the official ASHRAE design temperatures of 32°F (99% winter) and 95°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2A is cooling-dominated, solar heat gain control is critical. Jeff Davis homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

Jeff Davis Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2A in Jeff Davis, Georgia.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Jeff Davis HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your Jeff Davis blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Jeff Davis's exact design temperatures (32°F winter / 95°F summer).

Claim Free Report
No credit card required

Verify Your Jeff Davis ZIP Code

Enter your ZIP code to confirm it's in Jeff Davis and get climate zone details.

Jeff Davis covers 2 ZIP codes: 31532, 31539

Jeff Davis Design Temperatures

Official ASHRAE design temperatures for Jeff Davis, used for accurate Manual J load calculations.

Winter 99% Design Temp
32°F
Summer 1% Design Temp
95°F
Summer Wet Bulb
77°F

IECC Requirements for Zone 2A

Minimum insulation and window requirements for Jeff Davis per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Jeff Davis

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Jeff Davis

Upload your Jeff Davis blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

Jeff Davis design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report