What Climate Zone is Seminole, Florida?

Seminole is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official design temperatures for Seminole.

Climate Zone
2A
Winter Design
32°F
Summer Design
95°F
ZIP Codes
25

Seminole, Florida falls within IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. HVAC contractors working in Seminole must use the official ASHRAE design temperatures of 32°F (99% winter) and 95°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2A is cooling-dominated, solar heat gain control is critical. Seminole homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

Seminole Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2A in Seminole, Florida.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Seminole HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your Seminole blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Seminole's exact design temperatures (32°F winter / 95°F summer).

Claim Free Report
No credit card required

Verify Your Seminole ZIP Code

Enter your ZIP code to confirm it's in Seminole and get climate zone details.

Seminole covers 25 ZIP codes: 32701, 32707, 32708, 32714, 32730, 32732, 32746, 32750, 32765, 32766 and 15 more

Seminole Design Temperatures

Official ASHRAE design temperatures for Seminole, used for accurate Manual J load calculations.

Winter 99% Design Temp
32°F
Summer 1% Design Temp
95°F
Summer Wet Bulb
77°F

IECC Requirements for Zone 2A

Minimum insulation and window requirements for Seminole per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Seminole

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Seminole

Upload your Seminole blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

Seminole design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report