What Climate Zone is Okaloosa, Florida?

Okaloosa is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official design temperatures for Okaloosa.

Climate Zone
2A
Winter Design
32°F
Summer Design
95°F
ZIP Codes
18

Okaloosa, Florida falls within IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. HVAC contractors working in Okaloosa must use the official ASHRAE design temperatures of 32°F (99% winter) and 95°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2A is cooling-dominated, solar heat gain control is critical. Okaloosa homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

Okaloosa Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2A in Okaloosa, Florida.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Okaloosa HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your Okaloosa blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Okaloosa's exact design temperatures (32°F winter / 95°F summer).

Claim Free Report
No credit card required

Verify Your Okaloosa ZIP Code

Enter your ZIP code to confirm it's in Okaloosa and get climate zone details.

Okaloosa covers 18 ZIP codes: 32531, 32536, 32539, 32541, 32542, 32544, 32547, 32548, 32564, 32567 and 8 more

Okaloosa Design Temperatures

Official ASHRAE design temperatures for Okaloosa, used for accurate Manual J load calculations.

Winter 99% Design Temp
32°F
Summer 1% Design Temp
95°F
Summer Wet Bulb
77°F

IECC Requirements for Zone 2A

Minimum insulation and window requirements for Okaloosa per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Okaloosa

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER