What Climate Zone is Jackson, Florida?

Jackson is in IECC Climate Zone 2A (Hot - Humid). Get accurate Manual J load calculations with official design temperatures for Jackson.

Climate Zone
2A
Winter Design
32°F
Summer Design
95°F
ZIP Codes
13

Jackson, Florida falls within IECC Climate Zone 2A (Hot - Humid), a cooling-dominated region with humid moisture conditions. HVAC contractors working in Jackson must use the official ASHRAE design temperatures of 32°F (99% winter) and 95°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Because Zone 2A is cooling-dominated, solar heat gain control is critical. Jackson homes require windows with an SHGC of 0.25 or lower, along with R-13 wall insulation and R-30 ceiling insulation per the IECC 2021 energy code.

Jackson Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 2A in Jackson, Florida.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-13R-value
Floor InsulationR-13R-value
Window U-Factor0.4BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.25ACH50

Jackson HVAC Contractors: Get Your Free Manual J Report

Climate Zone 2A requires precise load calculations. Upload your Jackson blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Jackson's exact design temperatures (32°F winter / 95°F summer).

Claim Free Report
No credit card required

Verify Your Jackson ZIP Code

Enter your ZIP code to confirm it's in Jackson and get climate zone details.

Jackson covers 13 ZIP codes: 32420, 32423, 32426, 32431, 32432, 32440, 32442, 32443, 32445, 32446 and 3 more

Jackson Design Temperatures

Official ASHRAE design temperatures for Jackson, used for accurate Manual J load calculations.

Winter 99% Design Temp
32°F
Summer 1% Design Temp
95°F
Summer Wet Bulb
77°F

IECC Requirements for Zone 2A

Minimum insulation and window requirements for Jackson per IECC 2021.

Wall Insulation:R-13
Roof/Ceiling:R-30
Floor Insulation:R-13
Window U-Factor:0.4
Window SHGC:0.25

Energy Code: 2021 IECC

Recommended HVAC Equipment for Jackson

Heating Systems

Gas furnace
Heat pump
Electric resistance
Typical AFUE
80-92%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Jackson

Upload your Jackson blueprint and get a professional Manual J load calculation using official Zone 2A design temperatures. First report is FREE.

Jackson design temps
Zone 2A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Jackson contractors who trust AutoHVAC