What Climate Zone is Tioga County, PA?

Tioga County is in IECC Climate Zone 5A (Cool - Humid). Get accurate Manual J load calculations with official ASHRAE design temperatures for Tioga County.

IECC Climate Zone
5A
Winter 99% Design
3°F
Summer 1% Design
87°F
ZIP Codes
22
Cities
1

Tioga County, Pennsylvania is classified under IECC Climate Zone 5A (Cool - Humid), a heating-dominated region with humid moisture conditions. With 22 ZIP codes and 1 communities, every HVAC installation in Tioga County must use the ASHRAE design temperatures of 3°F (99% winter heating) and 87°F (1% summer cooling) for accurate Manual J load calculations.

As a heating-dominated zone, Tioga County requires robust insulation — a minimum of R-20 in walls, R-49 in ceilings, and R-30 in floors. Windows must meet a U-factor of 0.3 or lower. These requirements ensure homes maintain comfort during the coldest 3°F design conditions.

Tioga County Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance for Climate Zone 5A in Tioga County, PA.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Tioga County HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5A requires precise load calculations. Upload your Tioga County blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Tioga County's exact design temperatures (3°F winter / 87°F summer).

Claim Free Report
No credit card required

Verify Your Tioga County ZIP Code

Enter your ZIP code to confirm it's in Tioga County and get climate zone details.

Tioga County covers 22 ZIP codes including: 16901, 16911, 16912, 16917, 16918, 16920, 16921, 16928 and 14 more

Tioga County Design Temperatures

Official ASHRAE design temperatures for Tioga County, PA, used for accurate Manual J load calculations.

Winter 99% Design Temp
3°F
Heating load calculation baseline
Summer 1% Design Temp
87°F
Cooling load calculation baseline
Summer Wet Bulb
75°F
Latent load (humidity) calculation

IECC Zone 5A Insulation Requirements

Minimum insulation and window requirements for Tioga County per IECC 2021 energy code.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Climate Zone 5A: Cool - Humid - Heating-dominated climate with cold winters and warm, humid summers. High heating loads, moderate cooling needs.

Cities in Tioga County, PA

1 cities and communities in Tioga County share Climate Zone 5A requirements.

Recommended HVAC Equipment for Tioga County

Heating Systems

Gas furnace (95%+ AFUE)
Boiler
Heat pump (cold climate)
Typical AFUE
95-98%

Cooling Systems

AC (13-16 SEER)
Heat pump
Typical SEER
13-16 SEER

Nearby Counties in Pennsylvania

Compare climate zones with other counties in Pennsylvania. Different zones require different HVAC equipment sizing.

Get Free Manual J Calculations for Tioga County

Upload your Tioga County blueprint and get a professional Manual J load calculation using official Zone 5A design temperatures. First report is FREE.

Tioga County design temps
Zone 5A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Pennsylvania contractors who trust AutoHVAC