Climate ZonesConnecticutNew London County

What Climate Zone is New London County, CT?

New London County is in IECC Climate Zone 5A (Cool - Humid). Get accurate Manual J load calculations with official ASHRAE design temperatures for New London County.

IECC Climate Zone
5A
Winter 99% Design
7°F
Summer 1% Design
89°F
ZIP Codes
39
Cities
1

New London County, Connecticut is classified under IECC Climate Zone 5A (Cool - Humid), a heating-dominated region with humid moisture conditions. With 39 ZIP codes and 1 communities, every HVAC installation in New London County must use the ASHRAE design temperatures of 7°F (99% winter heating) and 89°F (1% summer cooling) for accurate Manual J load calculations.

As a heating-dominated zone, New London County requires robust insulation — a minimum of R-20 in walls, R-49 in ceilings, and R-30 in floors. Windows must meet a U-factor of 0.3 or lower. These requirements ensure homes maintain comfort during the coldest 7°F design conditions.

New London County Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance for Climate Zone 5A in New London County, CT.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-30R-value
Window U-Factor0.3BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

New London County HVAC Contractors: Get Your Free Manual J Report

Climate Zone 5A requires precise load calculations. Upload your New London County blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with New London County's exact design temperatures (7°F winter / 89°F summer).

Claim Free Report
No credit card required

Verify Your New London County ZIP Code

Enter your ZIP code to confirm it's in New London County and get climate zone details.

New London County covers 39 ZIP codes including: 06249, 06254, 06320, 06330, 06333, 06334, 06335, 06336 and 31 more

New London County Design Temperatures

Official ASHRAE design temperatures for New London County, CT, used for accurate Manual J load calculations.

Winter 99% Design Temp
7°F
Heating load calculation baseline
Summer 1% Design Temp
89°F
Cooling load calculation baseline
Summer Wet Bulb
75°F
Latent load (humidity) calculation

IECC Zone 5A Insulation Requirements

Minimum insulation and window requirements for New London County per IECC 2021 energy code.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-30
Window U-Factor:0.3
Window SHGC:0.4

Climate Zone 5A: Cool - Humid - Heating-dominated climate with cold winters and warm, humid summers. High heating loads, moderate cooling needs.

Cities in New London County, CT

1 cities and communities in New London County share Climate Zone 5A requirements.

Recommended HVAC Equipment for New London County

Heating Systems

Gas furnace (95%+ AFUE)
Boiler
Heat pump (cold climate)
Typical AFUE
95-98%

Cooling Systems

AC (13-16 SEER)
Heat pump
Typical SEER
13-16 SEER

Nearby Counties in Connecticut

Compare climate zones with other counties in Connecticut. Different zones require different HVAC equipment sizing.

Get Free Manual J Calculations for New London County

Upload your New London County blueprint and get a professional Manual J load calculation using official Zone 5A design temperatures. First report is FREE.

New London County design temps
Zone 5A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Connecticut contractors who trust AutoHVAC