What Climate Zone is Tulare, California?

Tulare is in IECC Climate Zone 3B (Warm - Dry). Get accurate Manual J load calculations with official design temperatures for Tulare.

Climate Zone
3B
Winter Design
35°F
Summer Design
99°F
ZIP Codes
41

Tulare, California falls within IECC Climate Zone 3B (Warm - Dry), a mixed-climate region with dry moisture conditions. HVAC contractors working in Tulare must use the official ASHRAE design temperatures of 35°F (99% winter) and 99°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 3B experiences both significant heating and cooling loads. Tulare homes need balanced insulation — R-20 walls, R-30 ceilings — plus windows with U-factor 0.32 and SHGC 0.25 per the IECC 2021 energy code.

Tulare Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 3B in Tulare, California.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-30R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.25Coefficient
Air Infiltration0.15ACH50

Tulare HVAC Contractors: Get Your Free Manual J Report

Climate Zone 3B requires precise load calculations. Upload your Tulare blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Tulare's exact design temperatures (35°F winter / 99°F summer).

Claim Free Report
No credit card required

Verify Your Tulare ZIP Code

Enter your ZIP code to confirm it's in Tulare and get climate zone details.

Tulare covers 41 ZIP codes: 93201, 93207, 93208, 93218, 93219, 93221, 93223, 93235, 93244, 93247 and 31 more

Tulare Design Temperatures

Official ASHRAE design temperatures for Tulare, used for accurate Manual J load calculations.

Winter 99% Design Temp
35°F
Summer 1% Design Temp
99°F
Summer Wet Bulb
68°F

IECC Requirements for Zone 3B

Minimum insulation and window requirements for Tulare per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-30
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.25

Energy Code: 2022 Title 24

Recommended HVAC Equipment for Tulare

Heating Systems

Gas furnace
Heat pump
Typical AFUE
90-95%

Cooling Systems

AC (14-16 SEER)
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Tulare

Upload your Tulare blueprint and get a professional Manual J load calculation using official Zone 3B design temperatures. First report is FREE.

Tulare design temps
Zone 3B compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report

Join 10,000+ Tulare contractors who trust AutoHVAC