What Climate Zone is El Dorado, California?

El Dorado is in IECC Climate Zone 4B (Mixed - Dry). Get accurate Manual J load calculations with official design temperatures for El Dorado.

Climate Zone
4B
Winter Design
3°F
Summer Design
92°F
ZIP Codes
30

El Dorado, California falls within IECC Climate Zone 4B (Mixed - Dry), a mixed-climate region with dry moisture conditions. HVAC contractors working in El Dorado must use the official ASHRAE design temperatures of 3°F (99% winter) and 92°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4B experiences both significant heating and cooling loads. El Dorado homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

El Dorado Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4B in El Dorado, California.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

El Dorado HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4B requires precise load calculations. Upload your El Dorado blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with El Dorado's exact design temperatures (3°F winter / 92°F summer).

Claim Free Report
No credit card required

Verify Your El Dorado ZIP Code

Enter your ZIP code to confirm it's in El Dorado and get climate zone details.

El Dorado covers 30 ZIP codes: 95613, 95614, 95619, 95623, 95633, 95634, 95635, 95636, 95651, 95664 and 20 more

El Dorado Design Temperatures

Official ASHRAE design temperatures for El Dorado, used for accurate Manual J load calculations.

Winter 99% Design Temp
3°F
Summer 1% Design Temp
92°F
Summer Wet Bulb
62°F

IECC Requirements for Zone 4B

Minimum insulation and window requirements for El Dorado per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2022 Title 24

Recommended HVAC Equipment for El Dorado

Heating Systems

Gas furnace (92%+ AFUE)
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Typical SEER
14-16 SEER