What Climate Zone is Izard, Arkansas?

Izard is in IECC Climate Zone 4A (Mixed - Humid). Get accurate Manual J load calculations with official design temperatures for Izard.

Climate Zone
4A
Winter Design
13°F
Summer Design
91°F
ZIP Codes
15

Izard, Arkansas falls within IECC Climate Zone 4A (Mixed - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Izard must use the official ASHRAE design temperatures of 13°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4A experiences both significant heating and cooling loads. Izard homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Izard Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4A in Izard, Arkansas.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Izard HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4A requires precise load calculations. Upload your Izard blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Izard's exact design temperatures (13°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Izard ZIP Code

Enter your ZIP code to confirm it's in Izard and get climate zone details.

Izard covers 15 ZIP codes: 72512, 72517, 72519, 72528, 72536, 72540, 72556, 72561, 72565, 72566 and 5 more

Izard Design Temperatures

Official ASHRAE design temperatures for Izard, used for accurate Manual J load calculations.

Winter 99% Design Temp
13°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 4A

Minimum insulation and window requirements for Izard per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Izard

Heating Systems

Gas furnace (90%+ AFUE)
Heat pump
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Izard

Upload your Izard blueprint and get a professional Manual J load calculation using official Zone 4A design temperatures. First report is FREE.

Izard design temps
Zone 4A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report