What Climate Zone is Baxter, Arkansas?

Baxter is in IECC Climate Zone 4A (Mixed - Humid). Get accurate Manual J load calculations with official design temperatures for Baxter.

Climate Zone
4A
Winter Design
13°F
Summer Design
91°F
ZIP Codes
12

Baxter, Arkansas falls within IECC Climate Zone 4A (Mixed - Humid), a mixed-climate region with humid moisture conditions. HVAC contractors working in Baxter must use the official ASHRAE design temperatures of 13°F (99% winter) and 91°F (1% summer) when performing Manual J load calculations. These values represent the outdoor conditions your heating and cooling system must handle 99% and 1% of the year, respectively — ensuring proper equipment sizing without costly over- or under-sizing.

Zone 4A experiences both significant heating and cooling loads. Baxter homes need balanced insulation — R-20 walls, R-49 ceilings — plus windows with U-factor 0.32 and SHGC 0.4 per the IECC 2021 energy code.

Baxter Insulation Requirements (IECC 2021)

Minimum insulation R-values and window performance requirements for Climate Zone 4A in Baxter, Arkansas.

Building ComponentMinimum RequirementUnit
Ceiling / Attic InsulationR-49R-value
Wall InsulationR-20R-value
Floor InsulationR-19R-value
Window U-Factor0.32BTU/hr-ft²-°F
Window SHGC0.4Coefficient
Air Infiltration0.15ACH50

Baxter HVAC Contractors: Get Your Free Manual J Report

Climate Zone 4A requires precise load calculations. Upload your Baxter blueprint and get a professional Manual J report in 60 seconds— first report is FREE. Pre-loaded with Baxter's exact design temperatures (13°F winter / 91°F summer).

Claim Free Report
No credit card required

Verify Your Baxter ZIP Code

Enter your ZIP code to confirm it's in Baxter and get climate zone details.

Baxter covers 12 ZIP codes: 72537, 72544, 72617, 72623, 72626, 72635, 72642, 72651, 72653, 72658 and 2 more

Baxter Design Temperatures

Official ASHRAE design temperatures for Baxter, used for accurate Manual J load calculations.

Winter 99% Design Temp
13°F
Summer 1% Design Temp
91°F
Summer Wet Bulb
75°F

IECC Requirements for Zone 4A

Minimum insulation and window requirements for Baxter per IECC 2021.

Wall Insulation:R-20
Roof/Ceiling:R-49
Floor Insulation:R-19
Window U-Factor:0.32
Window SHGC:0.4

Energy Code: 2021 IECC

Recommended HVAC Equipment for Baxter

Heating Systems

Gas furnace (90%+ AFUE)
Heat pump
Typical AFUE
92-96%

Cooling Systems

AC (14-16 SEER)
Heat pump
Typical SEER
14-16 SEER

Get Free Manual J Calculations for Baxter

Upload your Baxter blueprint and get a professional Manual J load calculation using official Zone 4A design temperatures. First report is FREE.

Baxter design temps
Zone 4A compliant
Ready in 60 seconds
Upload Blueprint - Get Free Report